Fanuc Parameter 1860 Full [verified] Jun 2026
An incorrect setting in Parameter 1860 will result in the machine moving an incorrect distance (e.g., commanding 100mm but moving 50mm or 200mm), rendering the machine unable to perform accurate machining or threading.
$$ \textDetection Unit = \frac\textScrew Pitch \times \textGear Ratio\textMotor Revs per Pulse \times 1821 $$ fanuc parameter 1860 full